ETEK-RCBO-EKL2-40
ETEK-RCBO-EKL2-40
ETEK-RCBO-EKL2-40
ETEK-RCBO-EKL2-40
ETEK-RCBO-EKL2-40
ETEK-RCBO-EKL2-40
ETEK-RCBO-EKL2-40

RCBO 6kA 1P+N Residual Current Operated Circuit Breaker

EKL2-40 offer a breaking capacity of 6 kA and only in one module meet the demand for devices that fully protect modern installations against short-circuit currents, overloads earth fault currents and indirect contacts, providing additional protection against direct contacts (30 mA versions).

● Standard: IEC61009-1
● Type: AC, A
● Rated current: 6~40A
● Rated voltage: 230/240~
● Number of poles: Single Pole
● Rated Residual Operating Current (IAn): 10,30, 100, 300mA
● Rated short-circuit breaking capacity: 6kA
● Tripping curve: B, C
● Ambient air temperature: -25...+40 ºC
● Connection: From bottom
● Certificates: CE, CB, UKCA, S

Inquire NOW PDF

RCBO 6kA 1P+N Residual Current Operated Circuit Breaker

Inquire NOW PDF

Porduct Overview

The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBO), EKL2-40 offer a breaking capacity of 6 kA and only in one module meet the demand for devices that fully protect modern installations against short-circuit currents, overloads earth fault currents and indirect contacts, providing additional protection against direct contacts (30 mA versions).

The commercial single module wide RCBO has an earth lead to ensure earth leakage detection, in case of accidental loss of neutral in the installation. 

These electronic RCBO can be installed in countries where the use of 1P+N RCBO with functional earth is consolidated.

 

Technical parameters

Technical Data

Standard IEC/EN61009-1

Protection

Ground fault, Overcurrent and short circuit, Over-voltage(selectable)

Type of trip

Ground fault: Electronic

Overload and short circuit: Thermo-magnetic

Type AC, A

No. of poles

1P+N,1 Module, N line with disconnected

Rated current In 6,10,16,20,25,32,40A

Rated sensitivity currents I△n

10,30,100,300mA
Residual current off-time under I△n ≤0.1s
Reted residual making and breaking capacity(I△m) 500A(In≤50A)
Rated voltage Ue 230/240V~
Rated frequency 50/60Hz
Rated breaking capacity 6,000A
Energy limiting class 3
Rated impulse withstand voltage (1.2/50) Uimp 4,000V
Dielectric test voltage at ind. Freq. for 1min 2kV

Thermal release characteristic

(1.13-1.45) x In

Magnetic release characteristic

B:(3-5) x In, C:(5-10) x In

Electrical life 4,000 Cycles
Mechanical life 10,000 Cycles
Contact position indicator Yes
Protection degree IP20
Ambient temperature -25℃~+40℃, Max.95% humidity
Terminal connection type Cable/Pin-type busbar

Max. terminal size for cable

L(in):25mm2, N/L(out): 16mm2
Max. tightening torque
L(in):2.5N.m, N/L(out): 2N.m

Installation

Mounting on 35mm DIN rail

Connection

From bottom

Dimensions

Circuit Diagram

etek rcbo ekl2-40 circuit diagram

Installation size

etek rcbo ekl2-40 size

Product selection form

Poles Rated Current (A) B Curve
Sensitivity
10mA 30mA 100mA 300mA
Type AC
1P+N 6A EKL2-40-1NB0610 EKL2-40-1NB0630 EKL2-40-1NB06100 EKL2-40-1NB06300
10A EKL2-40-1NB1010 EKL2-40-1NB1030 EKL2-40-1NB10100 EKL2-40-1NB10300
16A EKL2-40-1NB1610 EKL2-40-1NB1630 EKL2-40-1NB16100 EKL2-40-1NB16300
20A EKL2-40-1NB2010 EKL2-40-1NB2030 EKL2-40-1NB20100 EKL2-40-1NB20300
25A EKL2-40-1NB2510 EKL2-40-1NB2530 EKL2-40-1NB25100 EKL2-40-1NB25300
32A EKL2-40-1NB3210 EKL2-40-1NB3230 EKL2-40-1NB32100 EKL2-40-1NB32300
40A EKL2-40-1NB4010 EKL2-40-1NB4030 EKL2-40-1NB40100 EKL2-40-1NB40300
  Type A
6A EKL2-40-1NB0610A EKL2-40-1NB0630A EKL2-40-1NB06100A EKL2-40-1NB06300A
10A EKL2-40-1NB1010A EKL2-40-1NB1030A EKL2-40-1NB10100A EKL2-40-1NB10300A
16A EKL2-40-1NB1610A EKL2-40-1NB1630A EKL2-40-1NB16100A EKL2-40-1NB16300A
20A EKL2-40-1NB2010A EKL2-40-1NB2030A EKL2-40-1NB20100A EKL2-40-1NB20300A
25A EKL2-40-1NB2510A EKL2-40-1NB2530A EKL2-40-1NB25100A EKL2-40-1NB25300A
32A EKL2-40-1NB3210A EKL2-40-1NB3230A EKL2-40-1NB32100A EKL2-40-1NB32300A
40A EKL2-40-1NB4010A EKL2-40-1NB4030A EKL2-40-1NB40100A EKL2-40-1NB40300A
Poles Rated Current (A) C Curve
Sensitivity
10mA 30mA 100mA 300mA
Type AC
1P+N 6A EKL2-40-1NC0610 EKL2-40-1NC0630 EKL2-40-1NC06100 EKL2-40-1NC06300
10A EKL2-40-1NC1010 EKL2-40-1NC1030 EKL2-40-1NC10100 EKL2-40-1NC10300
16A EKL2-40-1NC1610 EKL2-40-1NC1630 EKL2-40-1NC16100 EKL2-40-1NC16300
20A EKL2-40-1NC2010 EKL2-40-1NC2030 EKL2-40-1NC20100 EKL2-40-1NC20300
25A EKL2-40-1NC2510 EKL2-40-1NC2530 EKL2-40-1NC25100 EKL2-40-1NC25300
32A EKL2-40-1NC3210 EKL2-40-1NC3230 EKL2-40-1NC32100 EKL2-40-1NC32300
40A EKL2-40-1NC4010 EKL2-40-1NC4030 EKL2-40-1NC40100 EKL2-40-1NC40300
  Type A
6A EKL2-40-1NC0610A EKL2-40-1NC0630A EKL2-40-1NC06100A EKL2-40-1NC06300A
10A EKL2-40-1NC1010A EKL2-40-1NC1030A EKL2-40-1NC10100A EKL2-40-1NC10300A
16A EKL2-40-1NC1610A EKL2-40-1NC1630A EKL2-40-1NC16100A EKL2-40-1NC16300A
20A EKL2-40-1NC2010A EKL2-40-1NC2030A EKL2-40-1NC20100A EKL2-40-1NC20300A
25A EKL2-40-1NC2510A EKL2-40-1NC2530A EKL2-40-1NC25100A EKL2-40-1NC25300A
32A EKL2-40-1NC3210A EKL2-40-1NC3230A EKL2-40-1NC32100A EKL2-40-1NC32300A
40A EKL2-40-1NC4010A EKL2-40-1NC4030A EKL2-40-1NC40100A EKL2-40-1NC40300A

Download Files

Document Type
Document Name
Size
Product Catalog
440.69KB
Product Certificate
874.01KB

Porduct Overview

The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBO), EKL2-40 offer a breaking capacity of 6 kA and only in one module meet the demand for devices that fully protect modern installations against short-circuit currents, overloads earth fault currents and indirect contacts, providing additional protection against direct contacts (30 mA versions).

The commercial single module wide RCBO has an earth lead to ensure earth leakage detection, in case of accidental loss of neutral in the installation. 

These electronic RCBO can be installed in countries where the use of 1P+N RCBO with functional earth is consolidated.

 

Technical parameters

Download Files

Get in Touch

Captcha Code
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All